Ventilatore VG70

Categoria:

Descrizione

ventilatore-carellato
ventilatore-carellato-2
previous arrow
next arrow
ventilatore-carellato
ventilatore-carellato-2
previous arrow
next arrow

Technical Specification

Ventilation Modes

  • VCV(A/C) – PCV(A/C) – PRVC – SIMV(VCV)+PSV
  • SIMV(PCV)+PSV SIMV(PRVC)+PSV – SPONT/CPAP+PSV
  • BIVENT+PSV – NIV/CPAP – NIV-T NIV-S/T

Parameters

  • Tidal Volume: 20~2000 ml
  • Respiration Rate: 1~80 bpm
  • Tinsp: 0.2~9 s
  • Tslope: 0~2 s
  • Tpause: 0~4 s
  • I:E Ratio: 1:10~4:1
  • FiO2: 21%~100%
  • Trigger Sensitivity: Pressure (-20~0 cmH2O, above PEEP)
  • Flow (0.5~20 LPM)
  • PEEP: 0~35 cmH2O
  • Psupport: 0~70 cmH2O
  • Pinsp: 5~70 cmH2O

Special Procedures

Apnea Ventilation – Smart Suction – Manual Breath

Insp/ Exp Hold – ETCO2 Measurement

Nebulization – Waveform Freeze

Monitoring

  • Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP
  • Volume / Flow Value: Vti, Vte, MV, MVspont
  • Time Value: ftotal,fspont, I:E
  • Real Time Curves: Pressure-Time, Flow-Time, Volume-Time waveforms
  • Pressure-Volume, Volume-Flow, Flow-Pressure loops
  • Gas Monitoring: FiO2, ETCO2
  • Calculated Values: Compliance(C)
    Resistance(R)
  • MVleak
  • RSBI
  • WOB
  • PEEPi

Alarm

  • Paw high / low – MVe high / low – Circuit disconnnect
  • FiO2 high / low – Inspiration / Expiratory tidal volume low
  • High Respiration Rate – Apnea – AC Failure – Nebulizer On
  • Low Battery – Air /O2 supply down – High / Low PEEP
  • Leakage out of range – Occlusion

Technical Data

  • Screen: 12〞TFT color touch screen (detachable)
  • Supply Gas: O2, 0.28~0.6 MPa
  • Power Supply: AC100~240 V, 50 Hz/60 Hz
  • Communication Interface: RS-232 Port, Nurse call Port, Ethernet Port
  • Dimension (WxDxH): 322 mm x 375 mm x 366 mm (Main Unit)
    547 mm x 675 mm x 950
  • Weight: 12.5 kg (Main Unit)
    25 kg (Cart)

Superior Mobile ICU ventilator

  • Comprehensive ICU ventilator including BIVENT and PRVC
  • Compact, big capacity battery, no air compressor, intra-hospital mobility
  • Flexible device configuration: equipped on a trolley, bed or ceiling pendant

Cost Effective Solution

  • Unique metal-based, autoclavable, heated exhalation valve
  • Built-in flow sensor, non-consumable design
  • Upgradeable ventilation system software, with an available USB port

Optimal patient-ventilator synchrony, increase patient comfort

  • The Unique Leak Compensation System – Keep precise control on the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically
  • Advanced Trigger Technique – Enhance sensitivity, avoid spurious triggering

Safe Ventilation Through Whole Treatment Phase

Initial Treatment Phase

  • Noninvasive ventilation mode associated with decreased intubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection
  • Preset patient’s height and IBW. Reduce clinician’s workload

Stable Condition Phase

  • PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation
  • Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant
  • Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient’s condition

Weaning Phase

  • Various ventilation modes enhance the weaning process
  • The unique trigger and leakage compensation system safeguards each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery
  • RSBI and WOB provide accurate reference for weaning

Rehab Phase

  • Data export port provides connection to hospital monitors and Patient Data Management Systems
  • Provides pressure support for the patient when spontaneous breathing is present

Other

  • 360° Visible Alarm Lamp
  • 12”TFT Detachable Touch Screen
  • Ultra Quiet Turbine Inside
  • Integrated Power Supply Solution
  • Built-in Battery, With Extended Backup Option